Standard procedures and what has changed at the bench
The standard operating procedure in force for each division is set out below, followed by the evolution of methods. Older reports remain valid records of what was done at the time; the timelines show what the laboratory would add today.
Standard operating procedures in force
8 procedures circulated to the divisions. Each states the examination sequence, the control checks that must accompany it and what has to appear on the face of the report.
SOP/DNA/04Autosomal STR profiling of biological exhibits
Rev 4.1 · effective April 2022
Applies to swabs, stains on cloth, tissue, blood in EDTA, bone and reference buccal swabs forwarded for individualisation or kinship comparison.
1. ReceiptVerify parcel count against the forwarding letter, photograph seals, and record any deviation before opening.
2. ScreeningScreen the stain with presumptive chemistry or a card test and map the sampled area on the exhibit sketch.
3. ExtractionAutomated silica column extraction; organic extraction with demineralisation for bone and calcified tissue.
4. QuantificationReal-Time PCR quantification with degradation index; select input volume from the quantification value, not by default.
5. AmplificationExpanded STR kit of the GlobalFiler class with positive control, negative control and reagent blank in every batch.
6. InterpretationApply the analytical and stochastic thresholds on record; interpret mixtures against the deconvolution worksheet before any comparison.
Quality control
Reagent blank and negative control in every extraction batch
Allelic ladder run with each capillary injection set
Second qualified examiner verifies every reported profile and exclusion
Reporting requirement
State the kit and loci examined, number of loci reported, and a random match probability or kinship statement. Partial profiles must carry an explicit statement of discriminatory power.
References
NABL 112 requirementsSWGDAM interpretation guidelinesSection 45, Indian Evidence Act
Applies to: DNA, Biology + DNA, Wildlife DNA
SOP/TOX/07Screening and confirmation of poisons in viscera and body fluids
Rev 7.0 · effective January 2021
Viscera, blood, urine, gastric lavage and suspected residue in poisoning, custodial death and unnatural death references.
Supersedes SOP/TOX/06 (screening by colour tests and TLC alone).
Examination sequence
1. ReceiptRecord preservative used, condition of jars and any leakage. Reject unsealed material with a written intimation.
2. PreliminaryColour and spot tests recorded as screening only, never as an identification.
3. ExtractionAcid, basic and neutral extraction as applicable; separate aliquot retained for confirmation.
4. ConfirmationGC-MS or LC-MS/MS against a certified reference standard run in the same batch.
5. QuantificationCalibration curve of not fewer than five points with a quality control sample at two levels.
6. RetentionRetain remnants under seal for the period prescribed so a re-examination remains possible.
Quality control
Certified reference standard in every confirmation batch
Solvent blank between samples to exclude carryover
Calibration verification recorded in the instrument log before analysis
Reporting requirement
Report the compound identified, the confirmatory technique used and the quantitative figure with units where the matrix allows. Screening-only findings must be stated as such.
References
NABL 112 chemical testing clausesSection 293, Indian Evidence ActCrPC 174 requirements
Applies to: Toxicology
SOP/BAL/03Firearm linkage, test firing and discharge residue
Rev 3.2 · effective August 2020
Seized firearms, fired cartridge cases, bullets, wads, clothing of the deceased and residue swabs from the hands or garments.
Examination sequence
1. ConditionExamine and photograph the firearm as received, record serviceability and trigger pull before any firing.
2. Test firingTest fire in the laboratory range with ammunition of the same calibre; retain test fired specimens under exhibit numbers.
3. ComparisonCompare breech face, firing pin and chamber marks under the comparison microscope; capture photomicrographs of agreeing detail.
4. ResidueModified Griess test for nitrite as a screen, followed by SEM-EDX for lead, barium and antimony particles.
5. RangeOpine on range only where the residue pattern and the control target series support it.
Quality control
Control target series fired at measured distances for every range opinion
Photomicrographs of the agreeing detail stored with the case file
Peer verification of every conclusive linkage
Reporting requirement
Record class and individual characteristics separately. Where deformation limits the comparison, the opinion must be qualified rather than stated as conclusive.
References
Arms Act 1959 examination requirementsAFTE range of conclusionsSection 45, Indian Evidence Act
Applies to: Ballistics, Physics
SOP/CYB/05Acquisition and examination of digital exhibits
Rev 5.3 · effective March 2023
Mobile handsets, storage media, computers, DVRs and cloud account data forwarded with authority.
SOP/NDPS/02Identification and purity determination of narcotic substances
Rev 2.4 · effective June 2022
Material seized under the NDPS Act, including samples drawn before a Magistrate under Section 52A.
Examination sequence
1. InventoryVerify the Section 52A inventory and the seal impression against the specimen seal before opening.
2. WeightRecord gross and net weight on a calibrated balance, with the weight of packing noted separately.
3. ScreeningMicroscopic examination and appropriate colour tests as a screen only.
4. IdentificationGC-MS or FTIR identification against a reference standard.
5. PurityHPLC quantification where the quantity classification in the charge depends on purity.
Quality control
Balance calibration verified on the day of weighing
Reference standard chromatogram appended to the analytical schedule
Remnant resealed with the laboratory seal and returned with the report
Reporting requirement
Report net weight, the substance identified, purity where determined, and the resulting quantity classification only as an arithmetical statement.
References
NDPS Act Sections 21, 52AStanding Order 1/88 samplingSection 293, Indian Evidence Act
Applies to: Narcotics
SOP/QD/06Comparison of handwriting and signatures
Rev 6.0 · effective November 2021
Questioned signatures and writings with admitted, specimen or contemporaneous comparison material.
Examination sequence
1. SufficiencyAssess whether the admitted material is contemporaneous and sufficient in quantity before beginning the comparison.
2. ExaminationStereomicroscopic examination of line quality, pen pressure, pen lifts and hesitation.
3. InstrumentationVideo spectral comparator for ink differentiation, erasures, additions and indented writing.
4. ComparisonRecord agreements and differences separately; note natural variation range of the writer.
Quality control
Photographic charts of the compared characteristics retained with the file
Second examiner review before any opinion of common authorship
Photocopy material examined only with a recorded limitation
Reporting requirement
State the material examined, the limitation arising from photocopies or insufficient specimens, and the opinion on the recognised scale.
References
Section 45 and Section 73, Indian Evidence ActASTM E2290 practice
Applies to: Questioned Documents
SOP/EXP/02Examination of post-blast debris and explosive residue
Rev 2.1 · effective February 2020
Debris, swabs, soil and control samples from explosion sites, and recovered bulk explosive or detonators.
Examination sequence
1. SegregationOpen debris parcels separately from residue swabs in different cabinets to exclude cross contamination.
2. ScreeningSpot tests for nitrate, nitrite and chlorate; thin layer chromatography for organic explosives.
3. ConfirmationFTIR for bulk material, ion chromatography for inorganic anions and GC-MS for organic residues.
4. ControlAnalyse the control soil or surface sample in parallel and report the comparison.
Quality control
Control sample analysed in the same batch as the questioned residue
Blank swab from the same lot analysed to exclude contamination
Delay between incident and collection recorded as a limitation
Reporting requirement
Identify the formulation class where the residue permits, and record contamination or delay as a limitation on the face of the report.
References
Explosive Substances Act 1908Section 45, Indian Evidence Act
Applies to: Explosives
SOP/BIO/03Serological screening of scene and body exhibits
Rev 3.0 · effective July 2019
Clothing, bedding, weapons, swabs and scene lifts examined for blood, semen and saliva.
Supersedes SOP/BIO/02 (Benzidine screening, withdrawn on health grounds).
Examination sequence
1. DryingAir dry damp exhibits in a controlled cabinet before examination and record the condition on receipt.
2. MappingMap and number every stain examined so the DNA sampling point can be traced back.
3. ScreeningPhenolphthalein for blood, microscopy for spermatozoa, card tests for human origin.
4. ReferralRefer positive stains for STR profiling on the same mapped area.
Quality control
Positive and negative controls with every card test lot
Separate instruments per exhibit to prevent transfer
Condition of damp or mouldy exhibits recorded before examination
Reporting requirement
Report screening results as presumptive unless a confirmatory test was applied, and state the species finding separately from individualisation.
References
NABL 112 biology clausesSection 45, Indian Evidence Act
Applies to: Biology & Serology, Biology + DNA
DNA profiling
Maharashtra laboratories moved from blood grouping and early multiplex kits to expanded STR panels with automated extraction and quantification.
Up to 2010Blood grouping and early RFLP work
Superseded
Association was mostly at class level through ABO grouping and absorption-elution. Individualisation was rarely possible and casework often stopped at species and group.
2010 to 2016AmpFlSTR Identifiler and Identifiler Plus
Superseded
Fifteen autosomal loci plus Amelogenin on ABI 3130xl platforms. Adequate for clean reference comparisons but thin on degraded or mixed material.
2016 to 2021PowerPlex 21 and mini-STR supplements
Still accepted
Twenty autosomal loci with better tolerance for inhibition. Mini-STR markers were added for degraded bone and tissue.
2021 onwardsExpanded kits, automation and probabilistic mixture work
Current practice
GlobalFiler class kits with 24 markers, automated extraction, Real-Time PCR quantification with degradation indices, and structured mixture interpretation. Current laboratory practice for fresh and challenged samples.
Toxicology
Screening has shifted from colour tests and TLC alone to instrument confirmation with quantification, which matters for weight in court.
Up to 2012Colour tests and thin layer chromatography
Superseded
Useful for screening but not sufficient on their own for a confirmed identification of a specific compound.
2012 to 2018GC and GC-MS confirmation
Still accepted
Gas chromatography with mass spectrometry became the confirmation standard for pesticides, alkaloids and volatiles.
2018 onwardsLC-MS/MS with quantification
Current practice
Liquid chromatography tandem mass spectrometry with calibrated quantification, plus AAS for heavy metals. Quantitative values are now expected wherever the matrix allows.
Ballistics and firearm discharge residue
Comparison microscopy remains the backbone, now supported by instrumental residue analysis and image documentation.
Up to 2014Comparison microscopy with chemical residue tests
Still accepted
Firing pin, breech face and striation comparison with Walker's test or modified Griess test for nitrite. Documentation was largely descriptive.
2014 to 2020Digital imaging and SEM-EDX for residue
Still accepted
Photomicrograph documentation of matching striations along with scanning electron microscopy and energy dispersive X-ray for particle level residue.
2020 onwardsInstrumented residue analysis with documented comparison sets
Current practice
SEM-EDX for characteristic lead, barium and antimony particles, ICP-MS where trace levels matter, and stored digital comparison images that can be re-examined.
Digital and cyber forensics
Tooling changes fast. The extraction method and tool version decide what can be recovered, so both belong in every report.
Up to 2015Manual examination and early imaging tools
Superseded
Photographs of screens, logical copies and limited deleted data recovery. Hashing was inconsistent across cases.
2015 to 2021Cellebrite UFED and Magnet AXIOM workflows
Still accepted
Physical and file system extraction with hash values recorded before and after examination, plus structured application parsing.
2021 onwardsCurrent suite with cloud and encrypted app support
Current practice
Later Cellebrite and AXIOM releases with full file system and keychain acquisition, cloud token handling, and Section 65B compliant certificates generated alongside the extraction.
Serology and biology
Serology is now a screening step that feeds DNA work rather than a stand-alone conclusion.
Up to 2012Benzidine, Takayama and ABO grouping
Superseded
Benzidine was later withdrawn from routine use on health grounds. Grouping gave class level association only.
2012 to 2018Phenolphthalein screening with precipitin species tests
Still accepted
Safer presumptive chemistry with anti-human precipitin for species origin, followed by referral for DNA where individualisation was needed.
Card based tests for blood, semen and saliva, followed by STR profiling on the same stain so the conclusion reaches individual level.
Method status at a glance
AmpFlSTR Identifiler Plus
Superseded
Standard until roughly 2016. Current practice: Expanded STR kits of the GlobalFiler class with automated extraction and Real-Time PCR quantification..
PowerPlex 21 System
Still accepted
Standard until roughly 2021. Current practice: Expanded 24 marker kits with degradation indices, retained for casework continuity where the earlier profile must be compared directly..
ABO grouping by absorption-elution
Superseded
Standard until roughly 2012. Current practice: Presumptive screening followed by STR profiling of the same stain for individual level association..
Benzidine test
Superseded
Standard until roughly 2012. Current practice: Phenolphthalein or card based immunochromatographic screening..
Takayama test
Still accepted
Standard until roughly 2015. Current practice: Confirmatory immunological tests with DNA referral for the same stain..
Colour tests and thin layer chromatography alone
Superseded
Standard until roughly 2012. Current practice: Screening followed by GC-MS or LC-MS/MS confirmation with quantification wherever the matrix allows..
Walker's test / modified Griess test
Still accepted
Standard until roughly 2018 as a stand-alone residue finding. Current practice: SEM-EDX for characteristic lead, barium and antimony particles, supported by the chemical test as a screen..
Cellebrite UFED 4PC
Still accepted
Standard until roughly 2021 for encrypted application data. Current practice: Current Cellebrite and Magnet releases with full file system acquisition, cloud token handling and a Section 65B certificate issued with the extraction..
Immunoassay screening without confirmation
Superseded
Standard until roughly 2015. Current practice: Immunoassay used only as a screen, with LC-MS/MS confirmation before reporting..